Dynamic peak value
Option P for TS 621
   moving peak value of tension
  Output 0 to 10V
  additionally to the standard output
  cut-off frequency selectable by DIP-Switch
•  0,5 / 5 / 10 / 20 Hz
 Zoom

Description
Option P offers a moving peak value acquisition of the measuring signal additionally to the standard output.
A peak of the tension signal is captured with its absolute value. This peak value gets erased over a defined time constant. The following filter changes it to a smooth signal.
The selectable cut-off frequencies ( fC ) are at 0,5Hz / 5Hz / 10Hz and 20Hz.

Why?
In rotating machines the acquisition of tension signals often is done disconiously, e.g. stranding machines.
The single wires get in contact with the sensor only for a short period of time.
This results in a periodical series of tension peaks.
This peaks are not usable for a tension control system.
Option P forms a filtered, moving peak value and provides the control unit a clear tension signal.




periodical tension signal - rectified and filtered