| | 2nd voltage output, filtered with additional amplification Option DX for TS 621 / TS 621 HD | |
| | • voltage output 0 to ±10V, filtered • additionally to the non-filtered standard output • cut-off frequency selectable by DIP-Switch 0,5 / 5 / 10 / 20 Hz • additional amplification selectable by DIP-Switch 2-, 3-, 4- or 5-times |
|
Description | |
Option DX offers a second, additional 0-10V output for strain gage amplifier TS 621. This output is filtered and additionally amplified by factor 2, 3, 4 or 5. The signal works in parallel to the fast voltage output. This option was designed to filter the parts with higher frequency - without useful content - out of the tension signal. Option DX includes a quad-selectable signal filter. In the region of the particular cut-off frequency the filter response curve drops steeply. This effects a pure tension signal.
The selectable cut-off frequencies ( fC ) are at 0,5Hz / 5Hz / 10Hz and 20Hz.
Filter response curve - logarithmic diagram
|
Why? | |
The tension signal typically contents parasitic parts of higher frequencies. These are caused by machine vibrations, excentricity, traverse movements, reactions from the material guidance and so on. For control purposes these signal parts are highly undesirable and interfering respectively. Option D filters these parts and supplies a pure tension signal.
Start animation with F5
Tension signal with parasitic signal part
filtered tension signal
fC = 5Hz
Tension signal with a dynamic part (frequency approx. 3Hz) Animation shows effects of filter without additional amplification. |
Block diagram | |
Related products | |
to product page | | TS 621 • for strain gauge sensors • optional outputs • 24V DC power supply • galvanic isolation
|
| | to product page | | TS 621 HD • for strain gage sensors • wide bandwidth: DC to 40kHz • 24V DC galv. isolated |
|
|
| | | PRODUCTS |
| | | | 2nd voltage output, filtered with additional amplification | |
|
|