| | Tensiotron® TS 621 Electronic precision measuring amplifier for strain gauge based sensors | |
| | • 24V DC power supply (19-36V DC) • galvanic isolation between power and meas.circuit • very compact, width only 25mm • additional second output Option D / A / X / DX / AD - D 0-10V, filtered with 0,5 / 5 / 10 / 20Hz - A 0/4-20mA, bipolar - X additional amplification factor 2x / 3x / 4x / 5x - DX additional amplification 2x / 3x / 4x / 5x and filter - AD 0/4-20mA, bipolar, filtered
|
|
Description | |
The Tensiotron® TS 621 electronic strain gauge amplifier combines the highest quality power and signal conditioning capabilities suitable for use with most strain gauge-based sensors, esp. for tension measurement. Best temperature and long-term stability as well as high accuracy are guaranteed by using modern technology. The TS 621 delivers superb performance features such as galvanic isolation, removable terminal block for the sensor connections, multiple options and high quality. |
Special features | |
• great noise immunity and service reliability for use in rough industrial operation • input power supply of 24V DC, reverse-polarity protected, providing - wide operating input power supply of 19-36V DC, LED indicates power-on status - integrated DC-DC converter for galvanic isolation between power supply and measuring circuit (very important to avoid ground loops in combination with secondary electronics) • provides a well-regulated power supply for sensor excitation, balanced to ground • coarse and fine adjustments for zero and amplification setting • width only 25mm • screw terminal for power and outputs • removable screw terminal plug for the sensor connections • standard: voltage output 0-10V, bipolar • optional outputs available: - option D > additional damped voltage output, selectable cut-off frequency 0.5 / 5 / 10 / 20Hz - option A > additional current output, selectable 0-20mA / 4-20mA, unipolar or bipolar - option X > additional voltage output, selectable amplification factor 2x, 3x, 4x, 5x - option DX > additional voltage output, filtered, with amplification 2x, 3x, 4x, 5x
|
PreView | |
Options | |
In standard version the strain gauge amplifier TS 621 offers a voltage output. The device can be extended by one additional output.
|
to product page | | 2nd voltage output, filtered • cut-off frequency 0,5 / 5 / 10 / 20 Hz • setting by DIP-switches • ordering code D |
InfoZoom | | 2nd voltage output with additional amplification • additional amplification 2x / 3x / 4x / 5x • setting by DIP-switches • ordering code X |
to product page | | 2nd voltage output, filtered with additional amplification • cut-off frequency 0,5 / 5 / 10 / 20 Hz • additional amplification 2x / 3x / 4x / 5x • setting by DIP-switches • ordering code DX |
InfoZoom | | Current output 0/4 - 20mA • unipolar / bipolar • setting by DIP-switches • ordering code A |
to product page | | Current output 0/4-20mA, filtered • unipolar / bipolar • cut-off frequency 0,5 / 5 / 10 / 20 Hz • setting by DIP-switches • ordering code AD |
to product page | | Dynamic peak value • cut-off frequency 0,5 / 5 / 10 / 20 Hz • setting by DIP-switches • ordering code P |
• supply voltage 12V DC (9-18V) instead of 24V DC • custom-specific gain • bridge excitation voltage 5V |
Measuring amplifier units with TS 621 | |
to product page | | MU 621 • measuring amplifier unit • 1 to 4 channels • digital display • 24V DC power supply |
Recommended periphery | |
to product page | | DPM 502 • LED-display, 3˝-digit • freely scalable • front-side operation • 24V DC power supply |
| | |
Accessories | |
InfoZoom | | Adapter TS 621-2/1-P • connects 2 sensors • parallel to plug-in direction |
| | InfoZoom | | Adapter TS 621-2/1-Q • connects 2 sensors • crosswise to plug-in direction |
| InfoZoom | | Switch cabinet TS621-1 • 1 channel design • rugged industry design • system of protection IP65 • installed ready for operation
|
| | |
Downloads | Note: Viewing of PDF-documents requires Adobe® Reader® - download |
|
| | | PRODUCTS |
| | |
|