| ![](/syspix/trans.gif) | RFS® 150 XY Radial force sensor with 2 measuring axis | ![](/syspix/trans.gif) |
![](/bilder/artikel/76047021_med.jpg) | | • measuring the radial force in x- and y-direction e.g. acquisition of axle loads and unbalance • easy to adapt • independent of force introduction point / lever arm • robust, stainless steel housing • available in 14 rated load ranges:
0 to 5N
LR - Low Range 0 to 10N ... 0 to 400N SR - Standard Range 0
to 500N ... 0 to 1kN HR
- High Range |
|
Description | ![](/syspix/trans.gif) |
The dual-axis radial force sensor offers two measuring axis, vertically to each other. Force introduction occurs radially at the bearing journal. Any acting force can be splitted vectorially into X- and Y-components.
Fields of application: • for research and industry • acquisition of axle loads, bearing reactions and unbalances • XY-force measurement on shafts and axles • force measurement on pivot joints and crankshafts • recording of polar force diagrams • biomechanics / orthopedy • flow measurements in wind tunel or flow channel • measurement of wind intensity and wind direction • winding and unwinding processes with varying geometry • force controlled joystick, e.g. control of a servo drive proportional to force
The high mechanical stiffness of the load cell enables measurement with virtually no excursion.
![](https://www.honigmann.com/syspix/trans.gif) The specified and calibrated accuracy remains unchanged throughout the unit’s service life and, across wide ranges, is independent of direct axial forces.![](https://www.honigmann.com/syspix/trans.gif)
![](https://www.honigmann.com/bilder/content/69230904_300.jpg) ![](https://honigmann.com/bilder/content/76077022_300.jpg) |
Both force signals get conditioned with a 2-channel measuring amplifier solution. Value and direction of the acting force are acquired. ![](https://www.honigmann.com/syspix/trans.gif) For analysis the data can be stored in the PC, e.g. with the software HCC-Easy.![](https://www.honigmann.com/syspix/trans.gif) Its export function enables the user to transfer the data to further software for extended analysis, e.g. generating a XY-diagram.
|
![](https://www.honigmann.com/bilder/content/69230906_500.jpg) Example: Polar diagram of the force in a crankshaft, force components against angle of rotation | |
![](/syspix/top.gif) | ![](/syspix/gelb.gif) |
Special features | ![](/syspix/trans.gif) |
• 2 measuring axis, vertically to each other • high overload protection • independent of the force introduction point, i.e. the sensor is not affected by lever arm action • no influence of any axial tilt torques or direct axial forces which might appear • robust, stainless steel housing • thought-through concept of housing for simple mounting |
Force ranges and bearing journals | ![](/syspix/trans.gif) |
![](https://honigmann.com/syspix/trans.gif)
Nominal force [N] |
|
Bearing journal Ø [mm] |
5* |
10 |
20 |
30 |
40 |
|
|
5 |
8 |
10 |
|
50 |
60 |
100 |
200 |
300 |
400 |
|
|
8 |
10 |
12 |
500** |
600** |
1000** |
|
|
|
|
|
|
10 |
12 |
![](https://honigmann.com/syspix/trans.gif)
The measuring range of the sensor begins at force’s zero point.
Bearing journals and nominal forces differing from the list are available.
* Special type LR (Low Range)
**Special type HR (High Range)
|
PreView | ![](/syspix/trans.gif) |
Options | ![](/syspix/trans.gif) |
![](/bilder/artikel/060825_tn.jpg) InfoZoom | ![](/syspix/trans.gif) | Seal gas protection • use with seal gas |
| ![](/syspix/trans.gif) | ![](/bilder/artikel/Vac1_tn.jpg) InfoZoom | ![](/syspix/trans.gif) | Vacuum design • in vacuum / high-vacuum |
|
Measuring amplifiers | ![](/syspix/trans.gif) |
![](/bilder/artikel/TS621_048_tn.jpg) to product page | ![](/syspix/trans.gif) | TS 621 • for strain gauge sensors • optional outputs • 24V DC power supply • galvanic isolation
|
| ![](/syspix/trans.gif) | ![](/bilder/artikel/TS481_041_II_tn.jpg) to product page | ![](/syspix/trans.gif) | TS 481 • for strain gauge sensors • 19” or mounting plate • 3 parallel outputs • 115 / 230V AC power supply |
| ![](/bilder/artikel/TS503_047_tn.jpg) to product page | ![](/syspix/trans.gif) | TS 503 • for strain gauge sensors • low cost • only 12,5mm wide • 24V DC power supply
|
| ![](/syspix/trans.gif) | ![](/bilder/artikel/MVE-02_001_tn.jpg) to product page | ![](/syspix/trans.gif) | MU 481-19" • for strain gauge sensors • 1 - 4 channels • digital display • rugged desktop housing |
|
Recommended periphery | ![](/syspix/trans.gif) |
| ![](/syspix/trans.gif) | ![](/bilder/artikel/DPM_103_II_tn.jpg) to product page | ![](/syspix/trans.gif) | DPM 502 • LED-display, 3½-digit • freely scalable • front-side operation • 24V DC power supply |
|
Accessories | ![](/syspix/trans.gif) |
![](/bilder/artikel/ft_03_tn.jpg) InfoZoom | ![](/syspix/trans.gif) | Bearing journal adapter • customer-specific • short-term delivery
|
| ![](/syspix/trans.gif) | ![](/bilder/artikel/Elektr_009_II_tn.jpg) InfoZoom | ![](/syspix/trans.gif) | Protection cap RFS • standard scope of supplies |
|
Similar products | ![](/syspix/trans.gif) |
![](/bilder/artikel/663794_tn.jpg) to product page | ![](/syspix/trans.gif) | RFS® 150 • single-roller system • for a wide variety of applications • easy to adapt • FN=> 1N to 3000N |
Downloads ![](/syspix/trans.gif) | Note: Viewing of PDF-documents requires Adobe® Reader® - download |
|
| ![](/syspix/trans.gif) | ![](/syspix/trans.gif) | PRODUCTS |
| ![](/bilder/artikel/Menuebild_RFS_XY.jpg) | |
|